Talking about the installation and advantages of Fire Proof Silicone Glass Fiber Braided Hose

December 26, 2022

(1) The Fire Proof Silicone Glass Fiber Braided Hose should be tested separately before installation. The chloride ion content of the test water should not exceed 25ppm. After passing the pressure test, it should be dried with clean compressed air in time and sealed for protection.

Pet Expandable Sleeving

(2) The installation of the Fire Proof Silicone Glass Fiber Braided hose must be carried out according to the design requirements and instructions for use, and any changes should be approved by the design.
(3) When installing the Fire Proof Silicone Glass Fiber Braided Hose, avoid extreme bending at the joint and its vicinity. Steel elbows can be used to keep the Fire Proof Silicone Glass Fiber Braided Hose in a straight line, and keep the Fire Proof Silicone Glass Fiber Braided Hose in the connection part in straight line
(4) During the installation of the pipeline, ensure that the installation axis of the Fire Proof Silicone Glass Fiber Braided Hose is in the same plane as its working direction, so as to avoid twisting of the Fire Proof Silicone Glass Fiber Braided Hose. In addition, when installing the Fire Proof Silicone Glass Fiber Braided Hose or Attention should also be paid to keeping the Fire Proof Silicone Glass Fiber Braided Hose in a free state when flanged, so as to prevent the Fire Proof Silicone Glass Fiber Braided Hose from being distorted by installation due to tightening the thread or dislocation of the screw hole of the connecting flange.
(5) When installing the Fire Proof Silicone Glass Fiber Braided Hose support and hanger, ensure that the movable pulley has sufficient movement. In addition, according to the actual situation of the installation site, in order to ensure that the Fire Proof Silicone Glass Fiber Braided Hose will not be twisted during work, a special bracket can be added. The addition of the lower baffle prevents the horizontal downward bending of the Fire Proof Silicone Glass Fiber Braided Hose; the addition of the upper baffle prevents the upward bending of the Fire Proof Silicone Glass Fiber Braided Hose caused by the impact of the medium.
(6) During the installation process, reliable protective measures should be taken on the outer surface of the Fire Proof Silicone Glass Fiber Braided Hose to prevent the steel wire of the mesh sleeve from being damaged or the bellows from being damaged.
(7) When welding near the Fire Proof Silicone Glass Fiber Braided Hose, the welding handle or wire should not touch the Fire Proof Silicone Glass Fiber Braided Hose to prevent the mesh sleeve from breaking or breaking down the bellows. Care should also be taken not to allow welding spatter to damage the mesh sleeve steel wire.
(8) The Fire Proof Silicone Glass Fiber Braided Hose cannot participate in the pressure test of the equipment piping system, let alone participate in the system purge. Prevent the debris in the system from impacting the inner wall of the fire-resistant silicone fiberglass braided hose and cause mechanical damage.
Anti-aging: Fire Proof Silicone Glass Fiber Braided Hose will become brittle, harden, crack, break and other aging phenomena under natural conditions, but Fire Proof Silicone Glass Fiber Braided Hose will not.
High temperature resistance: Fire Proof Silicone Glass Fiber Braided Hose is not resistant to high temperature, it will soften and catch fire when exposed to flames. The stainless steel body of the fire-resistant silicone fiberglass braided hose can withstand high temperatures, and the flame will only affect the outer PVC protective layer.
Anti-rat bites: Fire-resistant silicone fiberglass braided hose is easily bitten by mice, while the fire-resistant silicone fiberglass braided hose prevents rats from biting, because the teeth of ordinary animals cannot help the stainless steel pipe body.
Anti-shedding: Although the Fire Proof Silicone Glass Fiber Braided Hose will not fall off naturally after the clip is installed, it cannot guarantee the safety in case of aging shrinkage, external force pulling and other accidents. The Fire Proof Silicone Glass Fiber Braided Hose is generally connected with a screw thread, which can withstand the pulling of an adult and prevent accidental fall off.
Corrosion resistance: Fire Proof Silicone Glass Fiber Braided Hose is an organic material, not oil resistant, Fire Proof Silicone Glass Fiber Braided Hose can deal with common corrosive liquids, and the coated PVC protective layer also has a certain corrosion resistance.
Long lifespan: The service life of the fire-resistant silicone fiberglass braided hose is no more than two years, while the service life of the fire-resistant silicone fiberglass braided hose is at least 8 years, and the comprehensive calculation is cheaper.
Contact Us

Author:

Mr. hyhcablesleeve

Phone/WhatsApp:

+8613728648995

Popular Products
You may also like
Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

Copyright © 2024 Shenzhen Huiyunhai Tech.Co., Ltd. All rights reserved. Privacy Policy

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send